Monday, July 24, 2017
   
Text Size

Design Software Aids High-Performing Mixer Design

Parent Category: 2017 HFE

By NI AWR

Marki Microwave provides an extensive line of industry-leading, high-performance mixers that cover frequencies to 65 GHz, all built on a legacy of providing the best mixer performance in the world for over 20 years. Marki’s goal is to invent technologies to empower the RF and microwave industry to design faster, simplify production, eliminate complexity, and shatter performance barriers. This goal is achieved through intensive research, product development, and advanced and carefully controlled production. The company has a multi-decade legacy designing high performance microwave components, demonstrating technical leadership through collaboration with thousands of customers.

The Design Challenge

The company’s initial monolithic microwave integrated circuit (MMIC) mixers were nearly perfectly predicted using NI AWR Design Environment, specifically Microwave Office for circuit design, and the AWR Connected™ ANSYS HFSS partner solution for EM simulation. After successfully bringing to market its line of simple double-balanced mixers, Christopher Marki and his design team began focusing on improving the design process for its high-performance devices, which could only be made by hand and therefore could not effectively compete in the mass/high-volume market. The main T3 mixer line (Figure 1), Marki Microwave’s flagship IP, is the most sophisticated mixer circuit available. These mixers are designed for applications where intermodulation distortion (IP3 or two tone) and input power compression (1-dB compression) are system limitations. When provided with a square wave LO drive (generated by the integrated LO amplifier in T3A units) they provide the highest possible IP3, 1-dB compression, and spurious product prevention, particularly at frequencies below 10 GHz. The challenge was to make MMIC T3s in volume to complete in the mass volume market.

1706 HFE AppNote 01

Figure 1 • Marki Microwave’s T3 Mixer.

The Solution

There were many challenges to this undertaking, but thanks to Microwave Office, designers succeeded in proving the concept in Q2 2016 on their first try. “The parts looked great, very similar to simulation, and they were ready to go to market that summer,” commented Christopher Marki. Then, one morning, the design team had an idea and decided to make some tweaks to the design in Microwave Office. With a “flip of the wrist” simulation in the software, the nonlinear performance improved by 2-4 dB across the band. The extra performance was a huge deal because it meant the designers could essentially double the linearity for free, in other words, without making any other specification tradeoffs. Specifically, Marki went from mixers that were nominally about +28 dBm IP3 across the band to ones that achieved about +31 dBm across the band.

Every designer faces a choice during the design cycle: do I believe the software or not? Alternatively, the boss asks: “is it time to shoot the engineer and go to market?” Although he could not prove it, Christopher inherently believed in the harmonic balance solver within Microwave Office. The design team trusted their simulations and made a new mask set at significant expense. The new design worked perfectly. Figure 2 shows the original generation 1 versus the revised generation 2. The higher IP3 is the key spec the designers were looking for.

1706 HFE AppNote 02

Figure 2 • Gen 1 vs. the revised Gen 2.

Why NI AWR Design Environment

Christopher has been using Microwave Office for many years to design the highest quality mixers for customers who demand the best performance possible, and his confidence in the software paid off in a big way. Converting over to the new design delayed the overall production schedule slightly, however, in the end, the performance delta was clearly worth the wait and customers cannot believe how well the devices are made. In fact, the new ones are superior to the old parts by a noticeable margin in almost every spec. Better yet, Marki can attack high volume markets now because the devices are not built by hand like the traditional T3s. With the help of Microwave Office, Marki has unleashed the best mixer technology onto an IC platform, and this will revolutionize what customers will come to expect out of high performance mixers for years to come.

July 2017

1707 HFE cover

The July 2017 Online Edition is now available for viewing and download!

Download July HFE PDF

Search

Web Exclusives

Contact Us

Scott Spencer
Publisher
603-759-1840

Tim Burkhard
Associate Publisher
707-544-9977
Fax: 707-544-9375

Gary Rhodes
VP Sales
631-274-9530
Fax: 631-667-2871

Jeff Victor
Advertising Sales - Western U.S. - New Accounts
224-436-8044
Fax: 509-472-1888

Keith Neighbour
Advertising Sales - Central US
773-275-4020
Fax: 773-275- 3438

Sam Baird
Advertising Sales - UK and Europe
+44 1883 715 697
Fax: +44 1883 715 697

Zena Coupé
Advertising Sales - UK and Europe
+44 1923 852 537
Fax: +44 1923 852 261

Joanne Frangides
Advertising Sales - New Accounts & Product Showcase
201-666-6698
Fax: 201-666-6698

Coming Events

2017 USNC-URSI
(Joint with AP-S Symposium)
San Diego
July 9-15, 2017
      MILCOM 2017
Baltimore
October 23-25, 2017
     
IEEE EMC
Washington DC
August 7-11, 2017
  AOC
Washington DC
November 28-30, 2017
     
IEEE AUTOTESTCON
Anaheim
September 9-15, 2017
  2018 IEEE Radio and Wireless Symposium
Garden Grove
January 15-18, 2018 
     
EuMW2017
Nuremberg
October 8-13, 2017